Loop-mediated isothermal amplification (LAMP) has been widely applied in nucleic acid diagnostics due to its high sensitivity and specificity, high speed and low requirement of equipment. In order to fully leverage these merits, achieve high efficiency and reliability in diagnostics, and expand the applicable fields while keeping low reagent cost, multiplex LAMP technology has been extensively explored in recent years. Common methods for LAMP products detection are mostly based on the double-stranded DNA amplicons or byproducts from the polymerization reaction, so they can only identify the occurrence of amplification reaction but not the origins or specificity of the products. To achieve specific LAMP products detection, researchers developed various multiplex methods by improving the conventional LAMP technology or coupling LAMP with other assays. However, the interference and/or the different amplification efficiencies among different primer sets often lead to biased amplification and thus limited multiplexing level. We here defined these methods as narrow-sensed multiplex LAMP. The research on miniaturized amplification technology which is booming in recent years has given rise to the novel general-sensed multiplex LAMP technology that breaks this limitation by its capability to perform highly parallel and miniaturized simplex reactions in independent compartments. Methods of this type have additional benefits such as lower reagent cost, higher level of automation, lower risk of cross-contamination and better suitability for on-site detection of multiple targets. In this review, we summarize the recent research progress in multiplex LAMP technology from the following aspects: the principle and design of narrow-sensed LAMP and its amplification optimization, the general-sensed LAMP, and the various applications of all multiplex LAMP technologies in diagnostics.
[1] Notomi T, Okayama H, Masubuchi H, Yonekawa T, Watanabe K, Amino N, Hase T. Loop-mediated isothermal amplification of DNA. Nucl Acids Res , 2000, 28(12): e63.
[2] Nagamine K, Hase T, Notomi T. Accelerated reaction by loop-mediated isothermal amplification using loop primers. Mol Cell Probes , 2002, 16(3): 223-229.
[3] Mori Y, Nagamine K, Tomita N, Notomi T. Detection of loop-mediated isothermal amplification reaction by turbidity derived from magnesium pyrophosphate formation. Biochem Biophys Res Commun , 2001, 289(1): 150-154.
[4] Tomita N, Mori Y, Kanda H, Notomi T. Loop-mediated isothermal amplification (LAMP) of gene sequences and simple visual detection of products. Nat Protoc , 2008, 3(5): 877-882.
[5] Goto M, Honda E, Ogura A, Nomoto A, Hanaki K-I. Colorimetric detection of loop-mediated isothermal amplification reaction by using hydroxy naphthol blue. Biotechniques , 2009, 46(3): 167-172.
[6] Tanner NA, Zhang Y, EvansJr. TC. Visual detection of isothermal nucleic acid amplification using pH-sensitive dyes. Biotechniques , 2015, 58(2): 59-68.
[7] Mitsunaga S, Shimizu S, Okudaira Y, Oka A, Tanaka M, Kimura M, Kulski JK, Inoue I, Inoko H. Improved loop-mediated isothermal amplification for HLA-DRB1 genotyping using RecA and a restriction enzyme for enhanced amplification specificity. Immunogenetics , 2013, 65(6): 405-415.
[8] Zyrina NV, Zheleznaya LA, Dvoretsky EV, Vasiliev VD, Chernov A, Matvienko NI. N. BspD6I DNA nickase strongly stimulates template-independent synthesis of non-palindromic repetitive DNA by Bst DNA polymerase. Biol Chem , 2007, 388(4): 367-372.
[9] Hafner GJ, Yang IC, Wolter LC, Stafford MR, Giffard PM. Isothermal amplification and multimerization of DNA by Bst DNA polymerase. Biotechniques , 2001, 30(4): 852-856, 858, 860.
[10] Curtis KA, Rudolph DL, Owen SM. Sequence-specific detection method for reverse transcription, loop-mediated isothermal amplification of HIV-1. J Med Virol , 2009, 81(6): 966-972.
[11] Jiang YS, Bhadra S, Li B, Wu YR, Milligan JN, Ellington AD. Robust Strand Exchange Reactions for the Sequence-Specific, Real-Time Detection of Nucleic Acid Amplicons. Anal Chem , 2015, 87(6): 3314-3320.
[12] Liu XL, Zhao XT, Muhammad I, Ge BB, Hong B. Multiplex reverse transcription loop-mediated isothermal amplification for the simultaneous detection of CVB and CSVd in chrysanthemum. J Virol Methods , 2014, 210: 26-31.
[13] Liang C, Chu YN, Cheng SJ, Wu HP, Kajiyama T, Kambara H, Zhou GH. Multiplex loop-mediated isothermal amplification detection by sequence-based barcodes coupled with nicking endonuclease-mediated pyrosequencing. Anal Chem , 2012, 84(8): 3758-3763.
[14] Mori Y, Hirano T, Notomi T. Sequence specific visual detection of LAMP reactions by addition of cationic polymers. BMC Biotechnol , 2006, 6: 3.
[15] Khamlor T, Pongpiachan P, Parnpai R, Punyawai K, Sangsritavong S, Chokesajjawatee N. Bovine embryo sex determination by multiplex loop-mediated isothermal amplification. Theriogenology , 2014, 83(5): 891-896.
[16] Aonuma H, Yoshimura A, Kobayashi T, Okado K, Badolo A, Nelson B, Kanuka H, Fukumoto S. A single fluorescence-based LAMP reaction for identifying multiple parasites in mosquitoes. Exp Parasitol , 2010, 125(2): 179-183.
[17] Jung JH, Oh SJ, Kim YT, Kim SY, Kim W-J, Jung J, Seo TS. Combination of multiplex reverse-transcription loop-mediated isothermal amplification with an immunochromatographic strip for subtyping influenza A virus. Anal Chim Acta , 2015, 853: 541-547.
[18] Ngom B, Guo YC, Wang XL, Bi DR. Development and application of lateral flow test strip technology for detection of infectious agents and chemical contaminants: a review. Anal Bioanal Chem , 2010, 397(3): 1113-1135.
[19] Chow WHA, McCloskey C, Tong YH, Hu L, You QM, Kelly CP, Kong H, Tang YW, Tang W. Application of isothermal helicase-dependent amplification with a disposable detection device in a simple sensitive stool test for toxi